Samsung SDIINR18650-30Q(6)

Measured at Batemo: the Samsung SDI INR18650-30Q(6) delivers 238 Wh/kg energy density and sustains 41 W continuous power in a 18650 cell.

Opened, measured and modelled at Batemo in Karlsruhe, Germany · 196 measured parameters per cell · not datasheet values

Available asModelReportData

Dimensions
18.2 x 64.9mm
Mass
45.8 g
Internal resistance
Insights only — measured at Batemo, available in Batemo Insights
Spread across a measured batch
Insights only — measured at Batemo, available in Batemo Insights
Samsung SDI INR18650-30Q(6): the physical cell next to its Batemo model
The measured cell and its physical model
Samsung SDI INR18650-30Q(6)
238 Wh/kg · 1,544 W/kg
04,0008,0000250500power, W/kg →energy, Wh/kg →

this cell342 more sample cells

Show all 17 measured values — and 3 more behind the lock

ENERGY

Gravimetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

238Wh/kg
Volumetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

646Wh/L
Absolute energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, in watt-hours. Measured directly, not calculated from the nominal capacity. Full definition

10.91Wh

POWER

Gravimetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

1,544W/kg
Gravimetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

904W/kg
Volumetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

4,191W/L
Volumetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

2,453W/L
Absolute power, peak
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

70.7W
Absolute power, continuous
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

41.4W

CURRENT

Absolute current, peak
?

The highest constant discharge current Batemo measured the cell to sustain briefly, before the same 2.5 V / 80 °C stop condition applies. Full definition

20.4A
Absolute current, continuous
?

The highest constant discharge current Batemo measured the cell to sustain continuously, before the same 2.5 V / 80 °C stop condition applies. Full definition

12.1A

PHYSICAL

Dimensions
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

18.2 x 64.9mm
Mass
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

45.8g
Volume
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

16.9cm³
Format
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

18650

CELL

Absolute capacity, nominal
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

3.00Ah
Absolute capacity, measured (C/10)
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

2.97Ah
Mean voltage (C/10)
?

The charge-averaged voltage across the same C/10 discharge — the exchanged energy divided by the exchanged charge, not a single number picked from a curve. It is a measured mean, not the nominal voltage printed on a datasheet. Full definition

3.67V

In Batemo Insights

Impedance spectrum (EIS)
Insights only — measured at Batemo, available in Batemo Insights
Heat generation and thermal properties
Insights only — measured at Batemo, available in Batemo Insights
Capacity loss after formation
Insights only — measured at Batemo, available in Batemo Insights

What this cell does when you actually load it.

The table above gives you one capacity number. Below is what Samsung SDI INR18650-30Q(6) does under load — measured on our own test bench, across many operating points and several ambient temperatures. Every cell in the library is measured under identical conditions, which is what makes them comparable at all. At 1C — the one rate measured on every cell — usable energy is 87% to 99% of what the same cell delivers at C/10.

All three panels below use the same 11 measured operating points, at 25 °C ambient.

energy

11 pts · 25 °C · lin

How much energy can it deliver?

The graph visualizes how much energy the cell can deliver when operated at different powers.

usable energy / Wh

57911020406080

discharge power / W

At 25 °C ambient, Samsung SDI INR18650-30Q(6) delivers 5.5 Wh at 73 W — down from 10.9 Wh at C/10 (1.1 W).

thermal

11 pts · 25 °C · lin

How hot does it get?

The greater the thermal losses, the more the cell heats up, resulting in higher depleted power.

max. surface temperature / °C

20406080020406080

discharge power / W

At 25 °C ambient, Samsung SDI INR18650-30Q(6)'s surface reaches 80.0 °C at 73 W — up from 26.5 °C at C/10 (1.1 W).

runtime

11 pts · 25 °C · log

How long can it deliver the power?

The more power the cell supplies, the shorter it can deliver the power.

runtime to cutoff / s (log)

100100010k100k020406080

discharge power / W

At 25 °C ambient, Samsung SDI INR18650-30Q(6) runs for 5 min at 73 W — down from 9 h 55 min at C/10 (1.1 W).

The top 3 challenges you face with this cell.

Every cell is a compromise. This cell's own measurements point to three challenges you will face with it. Each one shows the number behind it and where Batemo helps you solve it.

Cell selection

Choosing the right cell

10.91Wh41W

and that is all a datasheet will tell you

Energy

second quarter of 343 cells

Continuous power

second quarter of 343 cells

the challenge

The datasheet says 3.00 Ah. But how much does it deliver in your system?

Looking at energy and power alone is not enough. Your duty cycle is neither C/10 nor 1 C, and somewhere in between the ranking between two cells can invert.

Cell selection

System optimization

Getting more from the pack

3.667V mean

this cell at C/10 — each dot a load case of an example cell

0

20

40

60

Ah/kg

C/10

1C

4C

8C

12C

datasheet

cut-off voltage

the challenge

My pack has several hundred of these. The decision is not about the cell any more — it is about the system.

An equivalent circuit fitted to a handful of measurements reproduces those points and drifts everywhere else — which is exactly where a system study goes.

System optimization

BMS development

Estimating the SOC

0–20.4A0–100% SOCup to 80°C

a BMS has to be right in every corner of this space

0

500

1000

W/kg

40 °C

25 °C

0 °C

−20 °C

hottest point

the challenge

Between 12.1 A and 20.4 A my state-of-charge estimate has to hold. Where does it get the worst?

Every percent of estimation error is paid for twice: once as range nobody uses, once as margin nobody touches.

BMS development

These three are the challenges this cell's own numbers raise. Which of them decides your product is something only your load profile can say — and that is the next question, not this one.

What the model of the Samsung SDI INR18650-30Q(6) answers that the measurement cannot.

Batemo built a physics-based model of the Samsung SDI INR18650-30Q(6) from the measurements above, then checked it against the full set of validation experiments — discharge, charge, pulses and profiles. Across all of them the model deviates from the measurement by 0.020 V in voltage and 0.8 K in surface temperature, in root mean square. These are deviations Batemo measured, not a tolerance Batemo promises.

“If you can show us another battery cell model that is more accurate, we will refund your money.”

BatemoOn every one of the 198 Batemo Cell Models in the library
Voltage
0.020V
0.6 % of the measured range
Temperature
0.8K
0.8 % of the measured range
Power
0.16W
0.7 % of the measured range
Energy
0.090Wh
1.4 % of the measured range

More on the Batemo Cell Model ›

Each value is the root mean square of the difference between measurement and simulation, across the full set of validation experiments for this cell — discharge, charge, pulses and profiles. A quarter of those experiments is known only to the party challenging the model, and not to Batemo. Model reference B0062.

How this cell sits in the field.

Nearest by measured specific energy and power — the two axes of the Ragone map above. Not by chemistry, and not a recommendation. Other numbers, like continuous current, can still differ a lot.

The two closest cells in the library

Also close · 2.9% apart

TENPOWER INR18650-30PG

18650
  • Gravimetric energy238 Wh/kg+0.0%
  • Gravimetric power, peak1,589 W/kg+2.9%
  • Absolute current, continuous14.8 A+22.0%
  • Mass46 g+0.0%
Open cell page
This cell at the center of a map of specific energy (horizontal) and specific peak power (vertical). Same build + closest behaviour: DMEGC INR18650-30P, 1.9% apart. Also close: TENPOWER INR18650-30PG, 2.9% apart.×1.10×0.91×1.10×0.91energy →power ↑2%5%

Ring percentages measure overall distance — energy and power combined. The ×-numbers on the dashed box measure just one axis: a point on that edge has that many times this cell's own specific energy or power.

  • This cell
  • Other cells, same build, in window

Same build + closest behaviour · 1.9% apart

DMEGC INR18650-30P

18650
  • Gravimetric energy241 Wh/kg+1.2%
  • Gravimetric power, peak1,567 W/kg+1.5%
  • Absolute current, continuous12.8 A+5.9%
  • Mass45 g-1.5%
Open cell page
What nextCompare cells