Great PowerGSP50160119F

Measured at Batemo: the Great Power GSP50160119F delivers 178 Wh/kg energy density and sustains 891 W continuous power in a prismatic cell.

Opened, measured and modelled at Batemo in Karlsruhe, Germany · 196 measured parameters per cell · not datasheet values

Available asBatemo InsightsBatemo Cell DataBatemo Cell ReportBatemo Cell Model

Dimensions
160 x 115 x 50mm
Mass
1,929.4 g
Internal resistance
(measured at Batemo, available in Batemo Insights)
Spread across a measured batch
(measured at Batemo, available in Batemo Insights)
Great Power GSP50160119F: the physical cell next to its Batemo model
The measured cell and its physical model
Great Power GSP50160119F
178 Wh/kg · 998 W/kg
04,0008,0000250500power, W/kg →energy, Wh/kg →

this cell353 more sample cells

Show all 17 measured values, and 3 more behind the lock

ENERGY

Gravimetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

178Wh/kg
Volumetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

372Wh/L
Absolute energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, in watt-hours. Measured directly, not calculated from the nominal capacity. Full definition

342.60Wh

POWER

Gravimetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating: the current behind it was measured on Batemo’s own test benches. Full definition

998W/kg
Gravimetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating: the current behind it was measured on Batemo’s own test benches. Full definition

462W/kg
Volumetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating: the current behind it was measured on Batemo’s own test benches. Full definition

2,090W/L
Volumetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating: the current behind it was measured on Batemo’s own test benches. Full definition

966W/L
Absolute power, peak
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

1,925.5W
Absolute power, continuous
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

890.5W

CURRENT

Absolute current, peak
?

The highest constant discharge current Batemo measured the cell to sustain briefly, before the same 2.5 V / 80 °C stop condition applies. Full definition

658.1A
Absolute current, continuous
?

The highest constant discharge current Batemo measured the cell to sustain continuously, before the same 2.5 V / 80 °C stop condition applies. Full definition

290.0A

PHYSICAL

Dimensions
?

Measured on the physical cell at Batemo in Karlsruhe, Germany, not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

160 x 115 x 50mm
Mass
?

Measured on the physical cell at Batemo in Karlsruhe, Germany, not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

1,929.4g
Volume
?

Measured on the physical cell at Batemo in Karlsruhe, Germany, not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

921.5cm³
Format
?

Measured on the physical cell at Batemo in Karlsruhe, Germany, not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

prismatic

CELL

Absolute capacity, nominal
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

100.00Ah
Absolute capacity, measured (C/10)
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

105.42Ah
Mean voltage (C/10)
?

The charge-averaged voltage across the same C/10 discharge: the exchanged energy divided by the exchanged charge, not a single number picked from a curve. It is a measured mean, not the nominal voltage printed on a datasheet. Full definition

3.25V

In Batemo Insights

Impedance spectrum (EIS)
(measured at Batemo, available in Batemo Insights)
Heat generation and thermal properties
(measured at Batemo, available in Batemo Insights)
Capacity loss after formation
(measured at Batemo, available in Batemo Insights)

Measured data for the Great Power GSP50160119F.

The Great Power GSP50160119F was measured on our own test bench, under the same conditions as every cell in the library. The curves below show how it behaves under load at 25 °C. They are a preview of the full data set. At 1C (the one rate measured on every cell), usable energy is 87% to 99% of what the same cell delivers at C/10.

All three panels below use the same 14 measured operating points, at 25 °C ambient.

energy

14 pts · 25 °C · lin

How much energy can it deliver?

The graph visualizes how much energy the cell can deliver when operated at different powers.

usable energy / Wh

100200300400010002000

discharge power / W

At 25 °C ambient, Great Power GSP50160119F delivers 141.3 Wh at 2,034 W, down from 342.6 Wh at C/10 (32 W).

thermal

14 pts · 25 °C · lin

How hot does it get?

The greater the thermal losses, the more the cell heats up, resulting in higher depleted power.

max. surface temperature / °C

204060010002000

discharge power / W

At 25 °C ambient, Great Power GSP50160119F's surface reaches 53.7 °C at 2,034 W, up from 26.3 °C at C/10 (32 W).

runtime

14 pts · 25 °C · log

How long can it deliver the power?

The more power the cell supplies, the shorter it can deliver the power.

runtime to cutoff / s (log)

100100010k100k010002000

discharge power / W

At 25 °C ambient, Great Power GSP50160119F runs for 4 min at 2,034 W, down from 10 h 33 min at C/10 (32 W).

The top 3 challenges you face with this cell.

Every cell is a compromise. This cell's own measurements point to three challenges you will face with it. Each one shows the number behind it and where Batemo helps you solve it.

BMS development

Estimating the SOC

0–658.1A0–100% SOCup to 60°C

a BMS has to be right in every corner of this space

0

500

1000

W/kg

40 °C

25 °C

0 °C

−20 °C

hottest point

the challenge

This cell runs anywhere between 0 A and 658.1 A. How wrong is my state of charge across that span?

Every percent of estimation error is paid for twice: once as range nobody uses, once as margin nobody touches.

More on BMS development

Thermal analysis

Getting the heat out

about 69mW/cm²

of heat at typical operation: 45 W in total

heat out

643 cm² of surface

the challenge

I push 891 W through each cell of my module. The sensor sits on the case. How far is it from the hot spot?

A surface temperature is not the temperature that decides. What no sensor on a finished cell can show is the temperature inside it, and the gap between the two grows exactly where it matters.

More on Thermal analysis

System optimization

Getting more from the pack

3.249V mean

this cell at C/10, each dot a load case of an example cell

0

20

40

60

Ah/kg

C/10

1C

4C

8C

12C

datasheet

cut-off voltage

the challenge

My load peaks at 658.1 A against 290.0 A continuous. Does the pack dip below cut-off, or does derating bite first?

An equivalent circuit fitted to a handful of measurements reproduces those points and drifts everywhere else, which is exactly where a system study goes.

More on System optimization

These three are the challenges this cell's own numbers raise. Which of them decides your product is something only your load profile can say, and that is the next question, not this one.

How accurate the model of the Great Power GSP50160119F is.

Batemo built a physics-based model of the Great Power GSP50160119F from its measurements, then checked it against the full set of validation experiments: discharge, charge, pulses and profiles. Across all of them the model deviates from the measurement by 0.029 V in voltage and 0.5 K in surface temperature, in root mean square. These are deviations Batemo measured, not a tolerance Batemo promises.

For simulation engineersThe model runs in MATLAB Simulink, MATLAB Simscape, Simcenter Amesim, AVL CRUISE M and as an FMU.

Get the model for this cell

“If you can show us another battery cell model that is more accurate, we will refund your money.”

BatemoOn every one of the 198 Batemo Cell Models in the library
Voltage
0.029V
1.0 % of the measured range
Temperature
0.5K
0.7 % of the measured range
Power
2.08W
0.7 % of the measured range
Energy
1.260Wh
1.0 % of the measured range

More on the Batemo Cell Model ›

Each value is the root mean square of the difference between measurement and simulation, across the full set of validation experiments for this cell: discharge, charge, pulses and profiles. A quarter of those experiments is known only to the party challenging the model, and not to Batemo.

How this cell sits in the field.

Nearest by measured specific energy and power, the two axes of the Ragone map above. Not by chemistry, and not a recommendation. Other numbers, like continuous current, can still differ a lot.

Among the 49 measured prismatic cells in the Batemo library, Great Power GSP50160119F holds rank 31 by gravimetric energy and rank 28 by gravimetric peak power. Against the median of these cells (181 Wh/kg and 1,018 W/kg), its gravimetric energy is −2% and its gravimetric peak power is −2%.

The two closest cells in the library

Also close · 2.9% apart

Gotion IFP53148115-104Ah

prismatic
  • Gravimetric energy181 Wh/kg+2.2%
  • Gravimetric power, peak1,018 W/kg+2.0%
  • Absolute current, continuous272.4 A-6.1%
  • Mass1,898 g-1.6%
Open cell page
This cell at the center of a map of specific energy (horizontal) and specific peak power (vertical). Same build + closest behaviour: EVE Energy LF105, 1.3% apart. Also close: Gotion IFP53148115-104Ah, 2.9% apart.×1.10×0.91×1.10×0.91energy →power ↑2%5%

Ring percentages measure overall distance, energy and power combined. The ×-numbers on the dashed box measure just one axis: a point on that edge has that many times this cell's own specific energy or power.

  • This cell
  • Other cells, same build, in window

Same build + closest behaviour · 1.3% apart

EVE Energy LF105

prismatic
  • Gravimetric energy179 Wh/kg+0.7%
  • Gravimetric power, peak1,009 W/kg+1.1%
  • Absolute current, continuous337.0 A+16.2%
  • Mass1,992 g+3.3%
Open cell page

More cells close to this one

Get model and dataCompare cells