Samsung SDICS1200R

Measured at Batemo: the Samsung SDI CS1200R delivers 205 Wh/kg energy density and sustains 913 W continuous power in a prismatic cell.

Opened, measured and modelled at Batemo in Karlsruhe, Germany · 196 measured parameters per cell · not datasheet values

Available asModelReportData

Dimensions
174 x 125.5 x 45mm
Mass
2,228.0 g
Internal resistance
Insights only — measured at Batemo, available in Batemo Insights
Spread across a measured batch
Insights only — measured at Batemo, available in Batemo Insights
Samsung SDI CS1200R: the physical cell next to its Batemo model
The measured cell and its physical model
Samsung SDI CS1200R
205 Wh/kg · 1,085 W/kg
04,0008,0000250500power, W/kg →energy, Wh/kg →

this cell342 more sample cells

Show all 17 measured values — and 3 more behind the lock

ENERGY

Gravimetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

205Wh/kg
Volumetric energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, divided by the cell’s mass or volume. Measured directly, not calculated from the nominal capacity. Full definition

461Wh/L
Absolute energy (C/10)
?

The energy exchanged during the C/10 discharge described under Capacity, in watt-hours. Measured directly, not calculated from the nominal capacity. Full definition

456.79Wh

POWER

Gravimetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

1,085W/kg
Gravimetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

410W/kg
Volumetric power, peak
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

2,442W/L
Volumetric power, continuous
?

The peak or continuous power above, divided by the cell’s mass or volume. Not a datasheet rating — the current behind it was measured on Batemo’s own test benches. Full definition

922W/L
Absolute power, peak
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

2,418.2W
Absolute power, continuous
?

Peak figures come from the highest current Batemo measured the cell to sustain briefly; continuous figures use the lower current it can sustain without interruption. Both stop at the same 2.5 V / 80 °C condition as the discharge measurements. Full definition

912.6W

CURRENT

Absolute current, peak
?

The highest constant discharge current Batemo measured the cell to sustain briefly, before the same 2.5 V / 80 °C stop condition applies. Full definition

700.8A
Absolute current, continuous
?

The highest constant discharge current Batemo measured the cell to sustain continuously, before the same 2.5 V / 80 °C stop condition applies. Full definition

269.1A

PHYSICAL

Dimensions
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

174 x 125.5 x 45mm
Mass
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

2,228.0g
Volume
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

990.2cm³
Format
?

Measured on the physical cell at Batemo, in Karlsruhe, Germany — not taken from the manufacturer's drawing. Volume is derived from the measured capacity and its volumetric density, not measured with a caliper. Full definition

prismatic

CELL

Absolute capacity, nominal
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

120.00Ah
Absolute capacity, measured (C/10)
?

Discharged from a full charge at a constant C/10 current and 25 °C, until the cell reaches 2.5 V or its surface reaches 80 °C. Nominal is the value from the datasheet; measured, gravimetric and volumetric are what Batemo recorded during that discharge. Full definition

123.89Ah
Mean voltage (C/10)
?

The charge-averaged voltage across the same C/10 discharge — the exchanged energy divided by the exchanged charge, not a single number picked from a curve. It is a measured mean, not the nominal voltage printed on a datasheet. Full definition

3.69V

In Batemo Insights

Impedance spectrum (EIS)
Insights only — measured at Batemo, available in Batemo Insights
Heat generation and thermal properties
Insights only — measured at Batemo, available in Batemo Insights
Capacity loss after formation
Insights only — measured at Batemo, available in Batemo Insights

What this cell does when you actually load it.

The table above gives you one capacity number. Below is what Samsung SDI CS1200R does under load — measured on our own test bench, across many operating points and several ambient temperatures. Every cell in the library is measured under identical conditions, which is what makes them comparable at all. At 1C — the one rate measured on every cell — usable energy is 87% to 99% of what the same cell delivers at C/10.

All three panels below use the same 11 measured operating points, at 25 °C ambient.

energy

11 pts · 25 °C · lin

How much energy can it deliver?

The graph visualizes how much energy the cell can deliver when operated at different powers.

usable energy / Wh

150250350450010002000

discharge power / W

At 25 °C ambient, Samsung SDI CS1200R delivers 181.1 Wh at 2,359 W — down from 456.8 Wh at C/10 (44 W).

thermal

11 pts · 25 °C · lin

How hot does it get?

The greater the thermal losses, the more the cell heats up, resulting in higher depleted power.

max. surface temperature / °C

204060010002000

discharge power / W

At 25 °C ambient, Samsung SDI CS1200R's surface reaches 57.5 °C at 2,359 W — up from 26.6 °C at C/10 (44 W).

runtime

11 pts · 25 °C · log

How long can it deliver the power?

The more power the cell supplies, the shorter it can deliver the power.

runtime to cutoff / s (log)

100100010k100k010002000

discharge power / W

At 25 °C ambient, Samsung SDI CS1200R runs for 5 min at 2,359 W — down from 10 h 20 min at C/10 (44 W).

The top 3 challenges you face with this cell.

Every cell is a compromise. This cell's own measurements point to three challenges you will face with it. Each one shows the number behind it and where Batemo helps you solve it.

BMS development

Estimating the SOC

0–700.8A0–100% SOCup to 60°C

a BMS has to be right in every corner of this space

0

500

1000

W/kg

40 °C

25 °C

0 °C

−20 °C

hottest point

the challenge

One cell of 123.89 Ah is a lot to be wrong about. How wrong is my state of charge?

Every percent of estimation error is paid for twice: once as range nobody uses, once as margin nobody touches.

BMS development

Fast charging

Charging it fast

From 100 % to 53% SOC in five minutes

discharging at measured peak current — the charge profiles above are schematic

time →

the challenge

700.8 A peak out of a single cell. On the charging side a different limit binds — how do I fast charge it?

CC-CV, stepped, constant power, boosted: every profile trades time against limits inside the cell that move each other. Which one is fastest for this cell, no datasheet says.

Fast charging

Lifetime

Making it last

123.89Ah

measured at C/10 — the schematic curves above all start here

cycles →

the challenge

This capacity describes the cell at the beginning of its life. How does it change under different operating conditions?

A cycle test tells you what happened under that one test. It does not tell you which mechanism took the capacity away, and it does not tell you what to change.

Lifetime

These three are the challenges this cell's own numbers raise. Which of them decides your product is something only your load profile can say — and that is the next question, not this one.

What the model of the Samsung SDI CS1200R answers that the measurement cannot.

Batemo built a physics-based model of the Samsung SDI CS1200R from the measurements above, then checked it against the full set of validation experiments — discharge, charge, pulses and profiles. Across all of them the model deviates from the measurement by 0.026 V in voltage and 0.7 K in surface temperature, in root mean square. These are deviations Batemo measured, not a tolerance Batemo promises.

“If you can show us another battery cell model that is more accurate, we will refund your money.”

BatemoOn every one of the 198 Batemo Cell Models in the library
Voltage
0.026V
0.8 % of the measured range
Temperature
0.7K
0.9 % of the measured range
Power
2.82W
0.6 % of the measured range
Energy
3.610Wh
1.4 % of the measured range

More on the Batemo Cell Model ›

Each value is the root mean square of the difference between measurement and simulation, across the full set of validation experiments for this cell — discharge, charge, pulses and profiles. A quarter of those experiments is known only to the party challenging the model, and not to Batemo. Model reference B0043.

How this cell sits in the field.

Nearest by measured specific energy and power — the two axes of the Ragone map above. Not by chemistry, and not a recommendation. Other numbers, like continuous current, can still differ a lot.

The two closest cells in the library

Also close · 15% apart

BYD Blade 2.0

prismatic
  • Gravimetric energy183 Wh/kg-10.9%
  • Gravimetric power, peak1,182 W/kg+8.9%
  • Absolute current, continuous403.8 A+50.0%
  • Mass2,500 g+12.2%
Open cell page
This cell at the center of a map of specific energy (horizontal) and specific peak power (vertical). Same build + closest behaviour: Gotion IFP53148115-104Ah, 15% apart. Also close: BYD Blade 2.0, 15% apart.×1.50×0.67×1.50×0.67energy →power ↑10%25%

Ring percentages measure overall distance — energy and power combined. The ×-numbers on the dashed box measure just one axis: a point on that edge has that many times this cell's own specific energy or power.

  • This cell
  • Other cells, same build, in window

Same build + closest behaviour · 15% apart

Gotion IFP53148115-104Ah

prismatic
  • Gravimetric energy181 Wh/kg-11.5%
  • Gravimetric power, peak1,018 W/kg-6.2%
  • Absolute current, continuous272.4 A+1.2%
  • Mass1,898 g-14.8%
Open cell page
What nextCompare cells